Lumenis VersaPulse PowerSuite 100W
BENEFITS OF USING A VERSAPULSE LASER
• The multi-specialty, multi-application platform offers superior cost
effectiveness and yield a high return on investment
• Most versatile laser systems for urology applications: BPH (BNI, TUIP,
HoLAP, HoLEP, HoLRP), stones, tumors and strictures
• Extensive clinical evidence; HoLAP and HoLEP have over 14
randomized controlled trials. Proven results spanning more than 10
years
• Provide standard of care for treating BPH (HoLAP & HoLEP) and
stones (in all locations): AUA and EAU support these as first line
treatment options1
• Precise and controlled cutting and ablation; penetrates just enough
to ablate tissue without charring, causing deep thermal necrosis or
collateral damage
• Effective for minimally invasive procedures requiring soft
tissue ablations, such as: BPH, stones, turbinate reduction and
endometriosis .
• Treatment of BPH
– Bladder Neck Incision (BNI)
– Transurethral Incision of the
Prostate (TUIP)
– Holmium Laser Ablation
of the Prostate (HoLAP)
– Holmium Laser Resection
of the Prostate (HoLRP)
– Holmium Laser Enucleation
of the Prostate (HoLEP)
• Lithotripsy of renal, ureteral
and bladder calculi
• Lithotripsy of impacted calculi
• Ureteral and urethral strictures
• Bladder and ureteral tumors
• Bladder carcinomasGASTROENTEROLOGY / GENERAL SURGERY
• Appendectomy
• Benign and malignant lesions
• Cholecystectomy
• Gall bladder and bile duct calculi
• Hemorrhoidectomy
• Lysis of adhesions
• Polypectomy
ORTHOPEDICS
• Capsular shift (LACS)
• Chondroplasty
• Excision of plica
• Lateral retinacular release
• Meniscectomy in the knee
• Osteoarthritic lesions
• Synovectomy
ENT
• Polyps and granulomas
• Tonsillectomy/adenoidectomy
• Partial turbinectomy
• Laryngeal lesions
THORACIC & PULMONARY
• Airway obstructions including
carcinoma
GYNECOLOGY
• Benign endometrial polyps
• Endometriosis
• Peritoneal adhesions
• Submucous fibroids
PODIATRY
• Neuromas
• Periungual, subungual and
plantar warts
• Radical nail excision
Holmium Laser
Enucleation
of the Prostate
(HoLEP)
Holmium Laser
Ablation
of the Prostate
(HoLAP)
Posterior Horn
Meniscectomy
Lithotripsy Laser Assisted
Capsular
Shift (LACS)
SPECIFICATIONS:
Single Wavelength, Holmium, 100 Watt
Wavelength: 2.1 microns
Repetition Rate: 5-50 Hz
Energy per Pulse: 0.2 – 3.5 J
Max. Tissue, Effect Setting: 2 J/50 Hz
Electrical: 208V, 50/60Hz, 30A Dual phase (For USA) | 230V, 60Hz, 30A Single Phase | 230V, 50Hz, 32A Single Phase
Pulse Duration: Up to 600 microseconds
Cooling: Cooling self-contained water-to-air exchanger
Delivery Systems: More than 20 reusable and single-use, flexible and rigid, with standard SMA connector
There are no reviews yet.